The webserver of the affected devices contains a vulnerability that may lead toa denial of service condition. An attacker may cause a denial of servicesituation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with networ...
7.5CVSS
7.3AI Score
0.001EPSS
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X...
9.8CVSS
9.5AI Score
0.013EPSS
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4" - 22" (incl....
7.5CVSS
7.3AI Score
0.002EPSS
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4" - 22" (incl....
9.8CVSS
9.3AI Score
0.006EPSS
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4" - 22" (incl....
7.5CVSS
7.3AI Score
0.004EPSS
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4" - 22" (incl....
7.5CVSS
7.4AI Score
0.002EPSS
SINAMICS medium voltage routable products are affected by a vulnerability in the Sm@rtServer component for remote access that could allow an unauthenticated attacker to cause a denial-of-service condition, and/or execution of limited configuration modifications and/or execution of limited control c...
9.8CVSS
9.5AI Score
0.002EPSS
The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products (SINAMICS SL150...
9.8CVSS
9.4AI Score
0.003EPSS